·

Engenharia Mecânica ·

Outros

Envie sua pergunta para a IA e receba a resposta na hora

Fazer Pergunta

Texto de pré-visualização

FilePROCRESFDESUEx35McQUISTONEES 08092020 103409 Page 1 EES Ver 10000 3996 anyone anyone FilePROCRESFDESUEx35McQUISTONEES 08092020 103411 Page 2 EES Ver 10000 3996 anyone anyone PROCESSO DE RESFRIAMENTO E DESUMIDIFICAÇÃO DADOS PRESSÃO BAROMÉTRICA P1101325 kPa ENTRADA VOLdot2000convertcfmm3s Tdb1converttempFC80 Twb1converttempFC67 SAIDA Tdb2converttempFC58 UR2080 umidade relativa TcondconverttempFC60 temperatura do condensado DETERMINE Qresf vazão em massa de condensado SOLUÇÃO OBTER AS PROPRIEDADES DA CARTA PSICROMETRICA PONTO 1 h1enthalpyAirH2OTTdb1BTwb1PP1 v1volumeAirH2OTTdb1BTwb1PP1 UR1relhumAirH2OTTdb1BTwb1PP1 omega1humratAirH2OTTdb1BTwb1PP1 Tdp1dewpointAirH2OTTdb1BTwb1PP1 CALCULO DA VAZÃO EM MASSA DE AR SECO ma1VOLdotv1 kgarsecos PONTO 2 FilePROCRESFDESUEx35McQUISTONEES 08092020 103411 Page 3 EES Ver 10000 3996 anyone anyone h2enthalpyAirH2OTTdb2RUR2PP1 omega2humratAirH2OTTdb2RUR2PP1 Twb2wetbulbAirH2OTTdb2RUR2PP1 v2volumeAirH2OTTdb2RUR2PP1 Tdp2dewpointAirH2OTTdb2RUR2PP1 CONDENSADO Tabela da Água Saturada hcondenthalpyWaterTTcondx0 liquido saturado ANALISE TERMODINÂMICA VC FLUXO DE AR CM ma1ma2 ar seco ma1omega1ma2omega2mcond 1ª LEI DA TERMODINÂMICA Qresfma1h1ma2h2mcondhcond Calulo do Qresf pelos Qsensivel e Qlatente Calor Sensivel cp1cpAirH2OTTdb1BTwb1PP1 cp2cpAirH2OTTdb2RUR2PP1 Qsensivel1ma1cp1Tdb1Tdb2 Qsensivel2ma1cp2Tdb1Tdb2 hxenthalpyAirH2OTTdb1womega2PP1 Qsensivel3ma1hxh2 Calor Latente hlvcondenthalpyvaporizationWaterTTcond FilePROCRESFDESUEx35McQUISTONEES 08092020 103411 Page 4 EES Ver 10000 3996 anyone anyone Qlatentemcondhlvcond Qresf1Qsensivel1Qlatente Qresf2Qsensivel2Qlatente Qresf3Qsensivel3Qlatente FATOR DE CALOR SENSIVEL SHF uso do tranSferidor na carta escala interna NA CARTA INCLINAÇÃO DA LINHA LIGANDO OS PONTOS 1 A 2 SHFQsensivel1absQresf SOLUTION Unit Settings SI C kPa kJ mass deg hcond 6524 kJkg hlvcond 2464 kJkg hx 4766 kJkg mcond 0003258 kgs mcond 0003258 kgs P1 1013 kPa Qlatente 8027 kW Qresf 217 kW Qresf 217 kW Qresf1 2171 kW Qresf2 2163 kW Qresf3 2163 kW Qsensivel1 1368 kW Qsensivel2 136 kW Qsensivel3 1361 kW SHF 06305 SHF 06305 Tcond 1556 C VOL 09439 m3s 9439 ls No unit problems were detected EES suggested units shown in purple for cp1 cp2 hcond hlvcond hx h1 Arrays Table Main hi Tdbi Twbi URi vi Tdpi i mai cpi kJkg C C m3kg C kgs kJkgK 1 5527 2667 1944 0511 08646 1573 001117 1092 1026 2 3519 1444 1246 08 08254 1104 0008186 1092 1019 FilePROCRESFDESUEx35McQUISTONEES 08092020 103411 Page 5 EES Ver 10000 3996 anyone anyone 0 5 10 15 20 25 30 35 40 0000 0005 0010 0015 0020 0025 0030 0035 0040 0045 0050 T C Humidity Ratio Pressure 1013 kPa 10C 15C 20C 25C 30C 35C 02 04 06 08 08 0825 085 m3kg 0875 09 0925 AirH2O 1 2 CALOR LATENTE CALOR SENSIVEL CALOR TOTAL X SHF063