·
Engenharia Elétrica ·
Instalações Elétricas
Send your question to AI and receive an answer instantly
Recommended for you
Preview text
1 CURSO DE ENGENHARIA DE ENGENHARIA ELÉTRICA 20171 AV4 DISCIPLINA INSTALAÇÕES ELÉTRICAS INDUSTRIAIS PROF DJALMA TAVARES ALUNO CAILAN AZEVEDO JADSON PAULO VITOR ALMEIDA 16062017 I ILUMINÂNCIA E CÁLCULO LUMINOTÉCNICO DE ACORDO COM AS NORMAS DA ABNT NBR 5413 CADA AMBIENTE REQUER UM DETERMINADO NÍVEL DE ILUMINÂNCIA E IDEAL ESTABELECIDO DE ACORDO COM AS ATIVIDADES A SEREM ALI DESENVOLVIDAS NO PROJETO ADOTAMOS UMA INDÚSTRIA DE ALIMENTOS COM AS CARACTERÍSTICAS QUE SEGUEM ABAIXO CLASSE B ÁREA DE TRABALHO EM GERAL TIPO DE AMBIENTE ATIVIDADES TRABALHOS NORMAIS ESCRITÓRIOS E FÁBRICAS CARACTERISTICAS DA TAREFA E DO OBSERVADOR IDADE INFERIOR A 40 ANOS PESO 1 VELOCIDADEPRECISÃO IMPORTANTE PESO 0 REFLETÂNCIA DO FUNDO DA TAREFA SUPERIOR A 70 PESO 1 𝑉𝑎𝑙𝑜𝑟 𝑡𝑜𝑡𝑎𝑙 𝑝𝑒𝑠𝑜𝑠 2 DE ACORDO COM A NORMA A ILUMINÂNCIA LUX A SER ESCOLHIDA É A MAIS BAIXA DO GRUPO COMO SEGUE A TABELA ABAIXO Logo 𝐸 1000 𝐿𝑈𝑋 AS DIMENSÕES DO LOCAL SEGUEM ABAIXO COMPRIMENTO DO AMBIENTE C 22 METROS LARGURA L 12 METROS ALTURA h 6 METROS 2 INDICE DO LOCAL K ILUMINAÇÃO DIRETA 𝐾 𝐶 𝐿 ℎ 𝐶 𝐿 22 12 6 22 12 129 TIPO DE LÂMPADA E ILUMINÁRIA TCK 4312 X TLTRS 110 W FATOR DE UTILIZAÇÃO FU COR DA PAREDE BRANCO COR DO TETO CLARO TIPO DE MATERIAL CONCRETO GRAU DE REFLEXÃO 20 A 50 EM FUNÇÃO DO ÍNDICE K O FATOR DE UTILIZAÇÃO DETERMINADO 𝐹𝑈 052 FATOR DE MANUTENÇÃO DO AMBIENTE FM CONSIDERANDO QUE O AMBIENTE É LIMPO 𝐹𝑀 09 CÁLCULO DA QUANTIDADE DE ILUMINÁRIAS N FLUXO LUMINOSO IM 𝜙 7600 𝑁 𝐸 𝑆 2𝜙 𝐹𝑈 𝐹𝑀 1000 264 15200 052 09 37 𝐼𝑙𝑢𝑚𝑖𝑛á𝑟𝑖𝑎𝑠 II DIMENSIONAMENTO DO CONDUTOR DA CARGA DE ILUMINAÇÃO 𝑃𝑜𝑡ê𝑛𝑐𝑖𝑎 37 110 4070 𝑤𝑎𝑡𝑡𝑠 CRITÉRIO DA MÁXIMA CORRENTE 𝐼 4070 220 185 𝐴 𝐼𝐶 185 087 2126 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 25 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑙 1 E 𝐿 1286 𝑀𝐸𝑇𝑅𝑂𝑆 𝑉 220 003 185 001286 2774 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 15 𝑚𝑚2 3 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA A CARGA DE ILUMINAÇÃO É DE 25 𝑚𝑚2 III DISTRIBUIÇÃO DAS CARGAS DE POTÊNCIA NA PLANTA INDUSTRIAL CCM 1 CCM 2 A B C D E F G I J H 2 x 3 F 2 x N T 3 F N T 3 F N T Bandejas CCM 1 CCM 2 A B C D E F G I J H a a a a a a a a a a a a a a a b b b b b b b b a 147 m b 141 m Carga H é composta de um motor de indução trifásico 380V 5CV 4 polos IpIn 66 Cosϕ 092 rendimento η091 FS 10 5CV 15A 𝐼 15 0577 25 1082 𝐴 CRITÉRIO DA MÁXIMA CORRENTE IC I 𝐹 𝐶 1082 087 1243 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 10 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑉 380 001 1082 001286 2730 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 15 𝑚𝑚2 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA A CARGA H É DE 15 𝑚𝑚2 TEMPERATURA DO AMBIENTE 𝟒𝟎𝑪 TIPO DA INSTALAÇÃO CABOS ISOLADOS DENTRO DE ELETRODUTOS OU CANALETAS ABERTAS OU FECHADAS COMPRIMENTO DO CCM2 ATÉ A CARGA H 1286 METROS VARIAÇÃO MÁXIMA DE QUEDA DE TENSÃO 𝑙 1 4 IV DIMENSIONAMENTO DO CABO DE ALIMENTAÇÃO DE ENTRADA 𝐼𝑇 185 1082 2932 𝐴 CRITÉRIO DA MÁXIMA CORRENTE 𝐼𝐶 2932 087 34 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 4 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑙 05 E 𝐿 846 𝑀𝐸𝑇𝑅𝑂𝑆 𝑉 380 0005 2932 000846 766 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 4 𝑚𝑚2 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA O CABO DE ALIMENTAÇÃO DE ENTRADA É DE 4 𝑚𝑚2
Send your question to AI and receive an answer instantly
Recommended for you
Preview text
1 CURSO DE ENGENHARIA DE ENGENHARIA ELÉTRICA 20171 AV4 DISCIPLINA INSTALAÇÕES ELÉTRICAS INDUSTRIAIS PROF DJALMA TAVARES ALUNO CAILAN AZEVEDO JADSON PAULO VITOR ALMEIDA 16062017 I ILUMINÂNCIA E CÁLCULO LUMINOTÉCNICO DE ACORDO COM AS NORMAS DA ABNT NBR 5413 CADA AMBIENTE REQUER UM DETERMINADO NÍVEL DE ILUMINÂNCIA E IDEAL ESTABELECIDO DE ACORDO COM AS ATIVIDADES A SEREM ALI DESENVOLVIDAS NO PROJETO ADOTAMOS UMA INDÚSTRIA DE ALIMENTOS COM AS CARACTERÍSTICAS QUE SEGUEM ABAIXO CLASSE B ÁREA DE TRABALHO EM GERAL TIPO DE AMBIENTE ATIVIDADES TRABALHOS NORMAIS ESCRITÓRIOS E FÁBRICAS CARACTERISTICAS DA TAREFA E DO OBSERVADOR IDADE INFERIOR A 40 ANOS PESO 1 VELOCIDADEPRECISÃO IMPORTANTE PESO 0 REFLETÂNCIA DO FUNDO DA TAREFA SUPERIOR A 70 PESO 1 𝑉𝑎𝑙𝑜𝑟 𝑡𝑜𝑡𝑎𝑙 𝑝𝑒𝑠𝑜𝑠 2 DE ACORDO COM A NORMA A ILUMINÂNCIA LUX A SER ESCOLHIDA É A MAIS BAIXA DO GRUPO COMO SEGUE A TABELA ABAIXO Logo 𝐸 1000 𝐿𝑈𝑋 AS DIMENSÕES DO LOCAL SEGUEM ABAIXO COMPRIMENTO DO AMBIENTE C 22 METROS LARGURA L 12 METROS ALTURA h 6 METROS 2 INDICE DO LOCAL K ILUMINAÇÃO DIRETA 𝐾 𝐶 𝐿 ℎ 𝐶 𝐿 22 12 6 22 12 129 TIPO DE LÂMPADA E ILUMINÁRIA TCK 4312 X TLTRS 110 W FATOR DE UTILIZAÇÃO FU COR DA PAREDE BRANCO COR DO TETO CLARO TIPO DE MATERIAL CONCRETO GRAU DE REFLEXÃO 20 A 50 EM FUNÇÃO DO ÍNDICE K O FATOR DE UTILIZAÇÃO DETERMINADO 𝐹𝑈 052 FATOR DE MANUTENÇÃO DO AMBIENTE FM CONSIDERANDO QUE O AMBIENTE É LIMPO 𝐹𝑀 09 CÁLCULO DA QUANTIDADE DE ILUMINÁRIAS N FLUXO LUMINOSO IM 𝜙 7600 𝑁 𝐸 𝑆 2𝜙 𝐹𝑈 𝐹𝑀 1000 264 15200 052 09 37 𝐼𝑙𝑢𝑚𝑖𝑛á𝑟𝑖𝑎𝑠 II DIMENSIONAMENTO DO CONDUTOR DA CARGA DE ILUMINAÇÃO 𝑃𝑜𝑡ê𝑛𝑐𝑖𝑎 37 110 4070 𝑤𝑎𝑡𝑡𝑠 CRITÉRIO DA MÁXIMA CORRENTE 𝐼 4070 220 185 𝐴 𝐼𝐶 185 087 2126 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 25 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑙 1 E 𝐿 1286 𝑀𝐸𝑇𝑅𝑂𝑆 𝑉 220 003 185 001286 2774 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 15 𝑚𝑚2 3 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA A CARGA DE ILUMINAÇÃO É DE 25 𝑚𝑚2 III DISTRIBUIÇÃO DAS CARGAS DE POTÊNCIA NA PLANTA INDUSTRIAL CCM 1 CCM 2 A B C D E F G I J H 2 x 3 F 2 x N T 3 F N T 3 F N T Bandejas CCM 1 CCM 2 A B C D E F G I J H a a a a a a a a a a a a a a a b b b b b b b b a 147 m b 141 m Carga H é composta de um motor de indução trifásico 380V 5CV 4 polos IpIn 66 Cosϕ 092 rendimento η091 FS 10 5CV 15A 𝐼 15 0577 25 1082 𝐴 CRITÉRIO DA MÁXIMA CORRENTE IC I 𝐹 𝐶 1082 087 1243 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 10 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑉 380 001 1082 001286 2730 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 15 𝑚𝑚2 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA A CARGA H É DE 15 𝑚𝑚2 TEMPERATURA DO AMBIENTE 𝟒𝟎𝑪 TIPO DA INSTALAÇÃO CABOS ISOLADOS DENTRO DE ELETRODUTOS OU CANALETAS ABERTAS OU FECHADAS COMPRIMENTO DO CCM2 ATÉ A CARGA H 1286 METROS VARIAÇÃO MÁXIMA DE QUEDA DE TENSÃO 𝑙 1 4 IV DIMENSIONAMENTO DO CABO DE ALIMENTAÇÃO DE ENTRADA 𝐼𝑇 185 1082 2932 𝐴 CRITÉRIO DA MÁXIMA CORRENTE 𝐼𝐶 2932 087 34 𝐴 LOGO PELO CRITÉRIO DA MÁXIMA CORRENTE O CONDUTOR A SER ADOTADO É DE 4 𝑚𝑚2 CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO 𝑙 05 E 𝐿 846 𝑀𝐸𝑇𝑅𝑂𝑆 𝑉 380 0005 2932 000846 766 𝑣 𝐴 𝑘𝑚 LOGO PELO CRITÉRIO DA MÁXIMA QUEDA DE TENSÃO O CONDUTOR A SER ADOTADO É DE 4 𝑚𝑚2 CONCLUSÃO O CONDUTOR A SER ADOTADO PARA O CABO DE ALIMENTAÇÃO DE ENTRADA É DE 4 𝑚𝑚2