4
Concreto Armado 2
PUC
4
Concreto Armado 2
PUC
10
Concreto Armado 2
PUC
2
Concreto Armado 2
PUC
8
Concreto Armado 2
PUC
26
Concreto Armado 2
PUC
3
Concreto Armado 2
PUC
1
Concreto Armado 2
PUC
6
Concreto Armado 2
PUC
2
Concreto Armado 2
PUC
Texto de pré-visualização
General characteristics of EEG High temporal resolution Low spatial resolution Direct measurement of neural activity High sensitivity to artifacts Portable and affordable suitable for bedside monitoring and research and electrical signal generated by brain cells General characteristics of fMRI High spatial resolution Low temporal resolution Measures blood flow as an indirect indicator of neural activity using a magnetic field Less sensitive to artifacts can be noisy and uncomfortable Expensive and less portable but provides detailed mapping of brain regions and Magnetic field generated by body LAJE DA MARQUISE Problema A marquise indicada na figura está vinculada na viga V01 Dimensionar e detalhar a laje da marquise e a viga V01 considerando as condições de segurança exigidas pela NBR6118 Adotar dimensões geométricas adequadas Definir os materiais a serem empregados P01 CORTE AB A B 600 cm P02 bw 300 cm LAJE DA MARQUISE hmin h V01 hmax bw 300 cm V01 bw x h Observações 1 A escolha das dimensões é livre 2 Você deve também definir os valores do fck e fyk dos materiais 3 A laje da marquise deve ser dimensionada à flexão e ao cisalhamento 4 A Viga V01 deve ser dimensionada à flexão ao cisalhamento e à torção 5 A laje e a viga devem ser detalhadas formas e armaduras
4
Concreto Armado 2
PUC
4
Concreto Armado 2
PUC
10
Concreto Armado 2
PUC
2
Concreto Armado 2
PUC
8
Concreto Armado 2
PUC
26
Concreto Armado 2
PUC
3
Concreto Armado 2
PUC
1
Concreto Armado 2
PUC
6
Concreto Armado 2
PUC
2
Concreto Armado 2
PUC
Texto de pré-visualização
General characteristics of EEG High temporal resolution Low spatial resolution Direct measurement of neural activity High sensitivity to artifacts Portable and affordable suitable for bedside monitoring and research and electrical signal generated by brain cells General characteristics of fMRI High spatial resolution Low temporal resolution Measures blood flow as an indirect indicator of neural activity using a magnetic field Less sensitive to artifacts can be noisy and uncomfortable Expensive and less portable but provides detailed mapping of brain regions and Magnetic field generated by body LAJE DA MARQUISE Problema A marquise indicada na figura está vinculada na viga V01 Dimensionar e detalhar a laje da marquise e a viga V01 considerando as condições de segurança exigidas pela NBR6118 Adotar dimensões geométricas adequadas Definir os materiais a serem empregados P01 CORTE AB A B 600 cm P02 bw 300 cm LAJE DA MARQUISE hmin h V01 hmax bw 300 cm V01 bw x h Observações 1 A escolha das dimensões é livre 2 Você deve também definir os valores do fck e fyk dos materiais 3 A laje da marquise deve ser dimensionada à flexão e ao cisalhamento 4 A Viga V01 deve ser dimensionada à flexão ao cisalhamento e à torção 5 A laje e a viga devem ser detalhadas formas e armaduras